Dual-Block Dry Bath TLDB100-2P
TLDB100-2P
Dual-Block Dry Baths deliver fast, stable, and precise heating for diverse laboratory applications. Their interchangeable blocks, uniform temperature, and intuitive controls enhance efficiency, reproducibility, and workflow flexibility.
-
Dual-block design with interchangeable modules
-
Stable heating for consistent sample results
-
Fast heat-up time for efficient laboratory operations
Rich Categories
Comfortable Use
Safety & Accessibility
Durable Build
Details
Details
The TLDB100-2P Dual-Block Dry Bath provides fast, precise heating for laboratory samples. Its dual-block design supports interchangeable modules, enabling flexible adaptation to various tube sizes. The device delivers consistent temperature distribution, ensuring sample integrity during incubation and reaction procedures.
The bath features an intuitive control interface for easy temperature adjustment and timing. Its compact design saves bench space while accommodating multiple sample formats simultaneously. Durable construction ensures long-term reliability in routine laboratory use.
-
Dual-block design with two interchangeable modules
-
Fast heating performance reduces waiting time
-
Stable and uniform temperature distribution
-
Intuitive digital interface for precise control
-
Compatible with a variety of tube formats
-
Compact design for efficient bench space use
-
Durable construction for long-term laboratory use
-
Ideal for DNA/RNA preparation, enzyme reactions, and sample incubation
-
Flexible configuration supports multiple experimental workflows
These features provide precise, reliable, and adaptable heating solutions for laboratory workflows.
Applications
Applications
-
DNA/RNA preparation and incubation
-
Enzyme reaction incubation
-
Sample digestion and processing
-
Molecular biology and biochemistry experiments
-
General laboratory heating and incubation tasks
Step 1
Step 2
Step 3
Step 4
Specification
Specification
| Parameter | TLDB100-2P |
| Temperature Range | Room temp −15℃ ~ 100℃ |
| Temperature Stability | ±0.5℃ |
| Temperature Homogeneity | ±0.5℃ |
| Display Accuracy | 0.1℃ |
| Heating Time | ≤12 min (25–100℃) |
| Cooling Time | (110×75×32 mm) × 2 |
| Multi-point Operation | No |
| Temperature Points Settable | 9 |
| Time Setting Range | 5 s – 24 h |
| Power | 5 s – 24 h |
| Voltage | AC 100–240 V |
| Size | 280×180×85 mm |
| Module Options | Numbers And Aperture Of Test Tube |
| DB1 | 96*0.2ml centrifuge tube |
| DB2 | 48*0.5ml centrifuge tube |
| DB3 | 35*1.5ml centrifuge tube |
| DB4 | 35*2.0ml centrifuge tube |
| DB5 | 24*5ml centrifuge tube |
| DB6 | 12*5/15ml centrifuge tube |
| DB7 | 6*50ml centrifuge tube |
| DB9 | Cuvettes dedicated module |
| DB2-1 | Aluminum beads (integral module, stand-alone) ( |